Chemistry · Analytical and physical chemistry · Year 1
Electrochemical analysis
How do we use an electric current to measure salt, fluoride and lead in water?
The situation
Three samples have been brought to a drinking-water monitoring laboratory in Tashkent: brackish water from a village well in the Aral Sea region, water from the city mains and water taken from the Akhangaran river. The chemist neither evaporates nor tastes them — he dips in electrodes, and within a few minutes the instruments show the salt content, the pH, the fluoride and even a few micrograms of lead per litre. How do electric current, potential and charge “tell” us the composition of a solution, and how far can these measurements be trusted?
Topic
Electrochemical analysis: conductivity, potentiometry, voltammetry. Drinking-water monitoring laboratory: brackish water brought from a well in the Aral Sea region in a conductivity meter, Tashkent tap water in a pH meter and a fluoride-selective electrode,…
Key ideas
- Conductometry
- Potentiometry
- Voltammetry
Formulas
Conductivity () and molar conductivity (); is the cell constant. [S·cm²/mol] = 1000· [S/cm] / [mol/L].
The Kohlrausch–Onsager law (strong 1:1 electrolyte, water, 25 °C: = 60.2, = 0.229) and the law of independent migration of ions.
Ostwald’s dilution law: the degree of dissociation of a weak electrolyte is found from conductivity.
Glass electrode: when the pH changes by one unit, the potential changes by 59.16 mV. The same holds in ionometry: .
The Ilkovič and Heyrovský–Ilkovič equations: wave height — quantity, half-wave potential — quality (which ion).
Theory
Electrolyte solutions: dissociation, activity, ionic strength
According to Arrhenius’s theory an electrolyte splits into ions in water; the fraction of dissociated molecules is the degree of dissociation . In a weak electrolyte (CH₃COOH, NH₃·H₂O) the equilibrium obeys the law of mass action: — Ostwald’s dilution law, : on dilution increases. In a strong electrolyte () each ion is surrounded by an ionic atmosphere of opposite charge (Debye–Hückel theory) — the “effective” concentration of the ion, its activity , is less than the analytical concentration. The ionic strength is ; the Debye–Hückel laws: (limiting, < 0.01) and (extended). So the thermodynamic constant (in activities) differs from the concentration constant , and a constant that takes account of the conditions of the medium (pH, a complexing agent) is a conditional constant. The analytical concentration is the total amount of dissolved substance, the equilibrium concentration is that of a particular species ([CH₃COO⁻], [CH₃COOH]). Theories of acids and bases: Arrhenius (gives H⁺ / OH⁻), Brønsted–Lowry (proton donor / acceptor), Lewis (electron-pair acceptor / donor); a buffer (CH₃COOH + CH₃COO⁻) keeps the pH steady — a pH meter is calibrated with buffers. The school-level treatment is in the “Electrolytic dissociation” and “Acids, bases and indicators” experiments.
Conductivity: κ, Λ, Kohlrausch and Onsager
A conductivity meter measures the resistance of the solution between two platinum plates: ; the cell constant is calibrated with 0.0100 mol/L KCl ( = 1.413 mS/cm at 25 °C). So that the electrodes do not polarise and no electrolysis takes place, alternating current (≈ 1 kHz) is used — low-frequency conductometry; in high-frequency (contactless) conductometry the electrodes do not touch the solution. Conductivity referred to one mole of electrolyte is the molar conductivity , and referred to one mole of equivalents it is the equivalent conductivity . In a strong electrolyte rises slowly on dilution — the Kohlrausch law ; the Onsager theory explains the slope by the relaxation and electrophoretic retardation of the ionic atmosphere. Extrapolation to gives (Physical chemistry L16). At infinite dilution the ions move independently: . H⁺ (349.8) and OH⁻ (198.6) are 2.5–7 times faster than other ions: the proton “hops” along a chain of water molecules (the Grotthuss mechanism). The transport number is the fraction of the current carried by that ion: in HCl ≈ 0.82, in KCl ≈ 0.49. In a weak electrolyte rises sharply on dilution because increases; its is found from the Kohlrausch law: = 390.7; then and (L17). If is plotted against , a straight line results: the intercept is , the slope . Direct conductometry: the salinity of water — dry residue ≈ (0.55–0.75)· [µS/cm] mg/L. increases by ≈ 2 % for each 1 °C rise in temperature, so the result is converted to 25 °C.
Conductometric titration
Indirect conductometry is finding the equivalence point in a titration from the break in the curve; no indicator is needed, and it also works in coloured and turbid solutions. When HCl is titrated with NaOH, the fast H⁺ (349.8) is replaced by the slow Na⁺ (50.1) — decreases; after the equivalence point the excess OH⁻ (198.6) raises it sharply: a “V”-shaped curve (Physical chemistry L19). In ethanoic acid there is little H⁺: as Na⁺ and CH₃COO⁻ form, rises slowly, and faster after the equivalence point. A mixture of HCl + CH₃COOH (L20) gives three straight-line segments: first HCl is neutralised ( falls), then CH₃COOH ( rises slowly), and at the end there is excess alkali. The break points: , . For the segments to be straight, a concentrated titrant is used (the volume changes little) or is corrected for dilution: . Direct conductometric determination (Analytical chemistry L22): from the of an ethanoic acid solution, if and are known, is found through Ostwald’s law.
Potentiometry and ionometry
The electrochemical cell: an indicator electrode (its potential depends on the ion being determined) and a reference electrode (its potential is constant: the saturated calomel electrode — +0.241 V, Ag/AgCl in saturated KCl — +0.197 V, relative to the standard hydrogen electrode). Almost no current flows (a high-impedance voltmeter), so the emf obeys the Nernst equation. Glass electrode: the difference between the H⁺ activities on the two sides of a thin glass membrane produces a potential, at 25 °C . A real electrode has an asymmetry potential and a slope slightly below 100 % — which is why a pH meter is calibrated with two buffers. Ion-selective electrodes (ionometry, Analytical chemistry L20): the fluoride electrode has a LaF₃ crystal membrane, ; to keep the ionic strength and pH the same, TISAB is added; the influence of other ions is taken into account by the Nikolsky equation (the selectivity coefficient). In reversible redox systems (Fe³⁺/Fe²⁺) the potential of a Pt electrode settles quickly and follows Nernst; in irreversible ones (MnO₄⁻/Mn²⁺, Cr₂O₇²⁻/Cr³⁺) it settles slowly and deviates from it. Potentiometric titration (Physical chemistry L22): the equivalence point is the steepest part of the pH(V) curve, the maximum of the first derivative . A polybasic acid, H₃PO₄, gives two jumps (p 2.15 and 7.20 → pH ≈ 4.7 and 9.6); the third (p 12.35) is not visible in water. In a mixture of HCl + CH₃COOH the first jump is small — conductometry distinguishes them more clearly.
Voltammetry: polarography and stripping analysis
The potential of the working electrode is changed linearly and the current is recorded. In classical polarography the working electrode is a dropping mercury electrode: the drop is renewed about every 4 s, the surface is always clean, and the overpotential for hydrogen evolution on mercury is large (≈ 1 V) — Zn²⁺ is reduced even at negative potentials. An excess of background electrolyte (0.1 mol/L KCl) eliminates migration: the ion reaches the electrode only by diffusion. When the potential is sufficient, the ions at the surface are reduced completely and the current reaches the limiting diffusion current — concentration polarisation. The Ilkovič equation (µA; in cm²/s, in mg/s, in s, in mmol/L): the height is proportional to the concentration — quantitative analysis. The Heyrovský–Ilkovič equation : the half-wave potential does not depend on concentration and identifies the ion — qualitative analysis. In 0.1 M KCl (relative to the saturated calomel electrode — SCE): Cu²⁺ +0.04 and −0.22, Pb²⁺ −0.40, Cd²⁺ −0.60, Zn²⁺ −1.00 V. Dissolved O₂ gives two waves (−0.05 and −0.9 V) — so nitrogen is bubbled through first. Stripping voltammetry (Analytical chemistry L21): metals are deposited onto a mercury film (an amalgam) at −1.2 V from a stirred solution, then dissolve again when the potential is scanned in the anodic direction; the peak height is proportional to — this is how Cd, Pb and Cu are determined at the µg/L level. The amount is found by the standard addition method: . If the electrode reaction itself is slow, kinetic polarisation (overpotential) is added — the Tafel equation is in the “Galvanic cells and corrosion” experiment.
Coulometry, safety and the model
Coulometry is based on Faraday’s laws: , , = 96 485 C/mol; the condition is 100 % current efficiency (the current is spent on only one reaction). In direct (potentiostatic) coulometry the substance being determined itself reacts at the electrode; the current falls exponentially with time, and the charge is accumulated by an electronic coulometer. If copper is deposited on a platinum gauze cathode and the cathode is weighed, this is electrogravimetry: if Cu is deposited from brass at −0.30 V (SCE), the zinc stays in the solution. The indirect method is coulometric titration: the titrant is generated at the electrode by a constant current (here ), and its amount is — neither a burette nor a standard solution is needed. Faraday’s laws themselves are in the “Electrolysis, Faraday's laws” experiment. Safety: mercury and its vapour are poisonous — mercury electrodes are used in a closed system, and spilled droplets are collected in a special way (today bismuth film electrodes are often used); wear safety goggles when working with acids and alkalis; fluoride solutions are poisonous — wear gloves; do not taste the solutions. Model: 25 °C; the ionic conductivities come from the extended form of the Onsager law (accurate to ≈ 1 % up to 0.1 mol/L), the pH and titration curves from the charge balance; the electrode slopes and asymmetry are typical values; and the Ilkovič parameters are from a handbook, from ; the sensitivity of the stripping peaks is a model; the composition of the samples (Aral Sea region, Tashkent, Akhangaran) is a teaching model, not a real measurement; in polarography and coulometry time is speeded up 10–120 times; the vibration of ions in alternating current is shown slowed down.
Did you know?
- Jaroslav Heyrovský created polarography in 1922 and received the Nobel Prize in Chemistry for this discovery in 1959; the equation of the diffusion current was derived in 1934 by his student Dionýz Ilkovič.
- The appearance of a potential across a glass membrane was observed in 1906 by the German physiologist Max Cremer; in 1909 Fritz Haber and Zygmunt Klemensiewicz used the glass electrode to measure acidity and in titration — today’s pH meter began there.
Inside the experiment
The experiment starts from a real-life situation: you predict the result, change the controls, run the experiment and draw a conclusion. Inside are missions, theory, a quiz and a guided tour in which the camera moves and explains the key points.
More experiments in this section
- Thermochemistry and Gibbs energy — Year 1
- Qualitative analysis and gravimetry — Year 2